THERMOCOUPLE     WIRE    
  Tolerance of Thermocouple Wire
Thermocouple
Types
JIS C   1602 - 1981
ANSI MC   96.1 - 1982
Temp. Range
Class
Limits of Error
Temp. Range
Class
Limits of Error
K (CA) 
     0 ~ 1200
     0 ~ 1000
-200 ~ 0
0.75
0.4
1.5
±2.5℃ or ±0.75%
±1.5℃ or ±0.4%
±2.5℃ or ±1.5%
     0 ~ 1250
     0 ~ 1250
-200 ~ 0
Standard
Special
Standard
±2.2℃ or ±0.75%
±1.1℃ or ±0.4%
±2.2℃ or ±2%
E (CRC)
     0 ~ 800
     0 ~ 800
-200 ~ 0
0.75
0.4
1.5
±2.5℃ or ±0.75%
±1.5℃ or ±0.4%
±2.5℃ or ±1.5%
     0 ~ 900
     0 ~ 900
-200 ~ 0
-200 ~ 0
Standard
Special
Standard
Special
±1.7℃ or ±0.5%
±1℃ or ±0.4%
±1.7℃ or ±1%
±1℃ or ±0.5%
J (IC)    
     0 ~ 750
     0 ~ 750
0.75
0.4
±2.5℃ or ±0.75%
±1.5℃ or ±0.4%
     0 ~ 750
     0 ~ 750
Standard
Special
±2.2℃ or ±0.75%
±1.1℃ or ±0.4%
T (CC)   
     0 ~ 350
     0 ~ 350
-200 ~ 0
0.75
0.4
1.5
±1℃ or ±0.75%
±0.5℃ or ±0.4%
±1℃ or ±1.5%
     0 ~ 350
     0 ~ 350
-200 ~ 0
-200 ~ 0
Standard
Special
Standard
Special
±1℃ or ±0.75%
±0.5℃ or ±0.4%
±1℃ or ±1.5%
±0.5℃ or ±0.8%

  MODEL CODE 

SPECIFICATION
□-□-□□-P-□╳1P
TYPE
K TYPE
T TYPE
J TYPE
K 
T 
J 
CLASS
0.75 %
0.4 %
0.75
0.4
INSULATION
and
SHEATH
PVC
Glass Fiber
Telflon
Silicone (MAX 200℃)
Ceramic Fiber (MAX 703℃)
Ceramic Fiber (MAX 1200℃)
Glass Fiber + Stainless Steel Wire to Weare
VV
GG
TT
SS
J7
JX
SU
SIZE
Conductor Diameter (mm)
Φ0.65
Φ0.51
Φ0.32
Φ0.25